			 Eorror Code  | 
			
			 Inverter  | 
			
			 Fix Speed  | 
		
| 
			 E0  | 
			
			 Internal temperature sensor error  | 
			
			 Indoor current transformer overcurrent protection  | 
		
| 
			 E1  | 
			
			 Room temperature sensor failure  | 
			
			 Room temperature sensor failure  | 
		
| 
			 E2  | 
			
			 External coil sensor error  | 
			
			 External coil sensor error  | 
		
| 
			 E3  | 
			
			 Internal coil sensor error  | 
			
			 Internal coil sensor error  | 
		
| 
			 E4  | 
			
			 Internal fan error of wall mounted air conditioner(PG/DC motor)  | 
			
			 Internal fan error of wall mounted air conditioner(PG/DC motor)  | 
		
| 
			 E5  | 
			
			 Internal and external communication error  | 
			
			 The communication between the display panel of the cabinet and the main control board is faulty.  | 
		
| 
			 E6  | 
			
			 Sliding door failure (L type)  | 
			
			 Sliding door failure (L type)  | 
		
| 
			 E7  | 
			
			 Same as F1  | 
			
			 Indoor anti-dry protection (high temperature failure)  | 
		
| 
			 F0  | 
			
			 External DC fan error (3-core terminal motor)  | 
			
			 /  | 
		
| 
			 F1  | 
			
			 Module protection error  | 
			
			 /  | 
		
| 
			 F2  | 
			
			 PFC protection error  | 
			
			 120N exhaust high temperature protection  | 
		
| 
			 F3  | 
			
			 Compressor startup error  | 
			
			 /  | 
		
| 
			 F4  | 
			
			 Exhaust sensor error  | 
			
			 /  | 
		
| 
			 F5  | 
			
			 Pressing top head sensor error  | 
			
			 /  | 
		
| 
			 F6  | 
			
			 External temperature sensor error  | 
			
			 /  | 
		
| 
			 F7  | 
			
			 OVP or UVP error  | 
			
			 /  | 
		
| 
			 F8  | 
			
			 Main external control panel and module panel communication error  | 
			
			 /  | 
		
| 
			 F9  | 
			
			 Outdoor EE error  | 
			
			 /  | 
		
| 
			 FA  | 
			
			 Recirculated sensor error(four-way valve switch error)  | 
			
			 /  | 
		
| 
			 Fb  | 
			
			 Cabinet internal fan error (see E4 for troubleshooting)  | 
			
			 Cabinet internal fan error (see E4 for troubleshooting)  | 
		
| 
			 P0  | 
			
			 Drainage system failure(AC)  | 
			
			 Drainage system failure(AC)  | 
		
| 
			 P1  | 
			
			 Water full alarm (AC)  | 
			
			 Water full alarm (AC)  | 
		
| 
			 P3  | 
			
			 Liquid deficiency protection  | 
			
			 Liquid deficiency protection  | 
		
| 
			 P9  | 
			
			 Display board and touchpad communication failure (L platform)  | 
			
			 Display board and touchpad communication failure (L platform)  | 
		
| 
			 L0  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 L1  | 
			
			 Same as F3  | 
			
			 /  | 
		
| 
			 L2  | 
			
			 Compressor startup failure  | 
			
			 /  | 
		
| 
			 L3  | 
			
			 Compressor Missing phase failure  | 
			
			 Same as F1  | 
		
| 
			 L4  | 
			
			 Same as F3  | 
			
			 /  | 
		
| 
			 L5  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 L6  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 L7  | 
			
			 Current detection AD abnormal protection  | 
			
			 /  | 
		
| 
			 L8  | 
			
			 shunt resistance imbalance fault  | 
			
			 /  | 
		
| 
			 L9  | 
			
			 IPM temperature sensor failure  | 
			
			 /  | 
		
| 
			 LA  | 
			
			 Same as F3  | 
			
			 /  | 
		
| 
			 LC  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 Ld  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 LE  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 LF  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 LH  | 
			
			 Same as F1  | 
			
			 /  | 
		
| 
			 H0  | 
			
			 Defrost  | 
			
			 Defrost  | 
		
 